Replace the thermal sensor, Powermax – Hypertherm Powermax105 Service Manual User Manual

Page 247

Advertising
background image

Power SuPPly ComPonent rePlaCement

powermax

105 Service Manual

9-49

Replace the thermal sensor

Complete the instructions below while referring to the applicable figure:

• 200-600 V CSA heat sink components on page 9-50
• 230-400 V CE, 380 V CCC/230-400 V CE heat sink components on page 9-51
• 380 V CCC/400 V CE heat sink components on page 9-52

1. Remove the upper left mounting screw from the inverter IGBT module.
2. Remove the thermal sensor.
3. Align the ring terminal of the new thermal sensor with the upper left hole in the inverter IGBT module.
4. Step torque the supplied mounting screw to the proper value as shown in the applicable figure.

Advertising
This manual is related to the following products: