TroubleshooTing and sysTem TesTs

powermax

105 Service Manual

8-33

Fault

code

Description

Power

lED

Fault

lED

Fault

icon

Solutions

3-20-0 Fill valve

Indicates that the Fill Valve is

not connected.

On

On

• Check the associated wiring.
• Perform Test 9.
• If necessary, replace the electronic

regulator. (Kit 228687)

3-20-1 Dump valve

Indicates that the Dump Valve

is not connected.

• Check the associated wiring.
• Perform Test 9.
• If necessary, replace the electronic

regulator. (Kit 228687)

3-20-2 Valve ID

The DSP does not recognize the electronic

regulator.
• Check the harness from the regulator to J6.

3-20-3 Electronic regulator is

disconnected
The electronic regulator is not

drawing current.

• Inspect the associated wiring, particularly

the 7-pin connector at J6 on the power

board.

• If necessary, replace the electronic

regulator.(Kit 228687)