0-nn-n

These fault codes identify operational faults. On the operator screen, the last digit is omitted. Display the service screen

for more information on faults 11, 19, 30, 40, 60, and 99.

Fault

code

Description

Power

lED

Fault

lED

Fault

icon

Solutions

0-11-0 Remote controller cut mode

invalid

On

Off

There is a problem with the remote controller

or the software interface to the system. The

system cannot interpret the cut mode, cut

current, or pressure information coming from

the controller.
• Fix the controller.
• Check the interface cable.

0-11-1 Remote controller current

invalid

0-11-2 Remote controller pressure

invalid

0-12-1 Output gas pressure low

On

Off

• Adjust the gas inlet pressure as needed.
• Check for kinked or blocked air lines.
• Perform Test 10.

0-12-2 Output gas pressure high

• The gas subsystem is not working properly.

Check the valve.

• Perform Test 10.

0-12-3 Output gas pressure unstable

Fault codes and solutions

Each table below describes a fault category and suggests solutions for each fault code. Several of the fault solutions

show a test number. Refer to page 8-42 System tests to perform the indicated numbered test.

Note: If a fault occurs while using a generator, turning the power switch quickly to OFF and then to ON again

(sometimes called a “quick reset”) may not clear the fault. Instead, turn OFF the power supply and wait 30 to

45 seconds before turning ON again.

0-00-0

This fault code indicates normal operations.

Fault

code

Description

Power

lED

Fault

lED

Fault

icon

Solutions

0-00-0 None

On

Off

-

No errors