85 a shielded cutting (mild steel), 85 a shielded cutting (mild steel) -22, Powermax – Hypertherm Powermax105 Service Manual User Manual

Page 94

Advertising
background image

Machine Torch SeTup

6-22

powermax

105

Service Manual

85 A Shielded cutting (Mild Steel)

Air flow rate – slpm/scfh

Hot

194 / 412

Cold

236 / 500

Metric

Material

thickness

torch-

to-Work

Distance

Initial Pierce

Height

Pierce

Delay

time

best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

mm

mm

mm

%

seconds

(mm/min)

Volts

(mm/min)

Volts

3

1.5

3.8

250

0.1

6800

122

9200

120

4

0.2

5650

122

7300

122

6

0.5

3600

123

4400

125

8

2500

125

3100

127

10

1680

127

2070

128

12

4.5

300

0.7

1280

130

1600

130

16

1.0

870

134

930

133

20

6.0

400

1.5

570

137

680

136

25

Edge Start

350

142

450

141

30

200

146

300

144

English

Material

thickness

torch-

to-Work

Distance

Initial Pierce

Height

Pierce

Delay

time

best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

inches

inches

inches

%

seconds

ipm

Volts

ipm

Volts

10GA

0.06

0.15

250

0.0

250

122

336

121

3/16

0.2

185

123

220

123

1/4

0.5

130

123

160

126

3/8

70

126

86

127

1/2

0.18

300

45

131

56

131

5/8

1.0

35

134

37

133

3/4

0.24

400

1.5

24

136

29

135

7/8

Edge Start

19

139

22

138

1

13

142

17

141

1-1/8

9

145

13

143

1-1/4

7

148

10

146

Advertising