Power SuPPly ComPonent rePlaCement

powermax

105 Service Manual

9-81

6. Disconnect the quick disconnect receptacle from the front end panel by removing the four mounting screws.
7. Remove the bolt securing the work cable to the work lead receptacle.
8. Remove the nut and washer securing work lead receptacle to the front end panel.
9. Push the work lead receptacle out through the front end panel.

Quick disconnect

receptacle

Mounting screws (4)

Front end panel

Bolt

Nut

Washer

Work cable

Work lead

receptacle