85 a shielded cutting (stainless steel), 85 a shielded cutting (stainless steel) -23, Powermax – Hypertherm Powermax105 Service Manual User Manual

Page 95

Advertising
background image

Machine Torch SeTup

powermax

105 Service Manual

6-23

85 A Shielded cutting (Stainless Steel)

Air flow rate – slpm/scfh

Hot

194 / 412

Cold

236 / 500

Metric

Material

thickness

torch-

to-Work

Distance

Initial Pierce Height

Pierce

Delay time

best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

mm

mm

mm

%

seconds

(mm/min)

Volts

(mm/min)

Volts

3

1.5

3.8

250

0.1

7500

122

9200

120

4

0.2

6100

122

7500

120

6

0.5

3700

122

4600

122

8

2450

124

3050

124

10

4.5

300

1550

127

1900

126

12

0.7

1100

131

1400

130

16

1.0

700

135

760

134

20

Edge Start

480

138

570

137

25

300

143

370

141

English

Material

thickness

torch-

to-Work

Distance

Initial Pierce Height

Pierce

Delay time

best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

inches

inches

inches

%

seconds

ipm

Volts

ipm

Volts

10GA

0.06

0.15

250

0.2

275

122

336

120

3/16

200

122

240

121

1/4

0.5

130

122

164

122

3/8

65

126

80

125

1/2

0.18

300

36

132

48

131

5/8

1.0

28

135

30

134

3/4

Edge Start

20

137

24

136

7/8

16

140

19

139

1

11

143

14

141