TroubleshooTing and sysTem TesTs

8-26

powermax

105

Service Manual

Fault

code

Description

Power

lED

Fault

lED

Fault

icon

Solutions

0-13-0 AC input unstable (line

resonance): Warning.

Blinks

(3 Hz)

Off

• Perform a cold restart.
• If the fault does not clear, correct the

power source. Change the character,

generally the impedance, of the line.

0-19-9 Power board hardware

protection. One or more major

power board hardware faults

(or electrical noise) detected:

Warning.
Fault 0-19-9 can occur three or

more times before becoming a

0-99 fault.
If fault code 0-19 appears upon

power-up, wait one minute to

see if fault code 0-99 appears.

This could indicate a faulty

auxiliary switch.

On

On

The inverter shuts down and does not fire

again for several seconds. If the fault is

caused by electrical noise, the fault clears

in a few seconds and the machine operates

normally.
If a true fault continues to occur, the 0-99

fault code appears on the operator screen:
• Access the fault log in the service screen

to identify the major fault.

• Perform Test 12 if fault code 0-99 occurs

after fault code 0-19 displays for one

minute.

0-20-0 Low gas pressure

The gas pressure has fallen

below the minimum pressure for

that process, mode, and lead

length.

On

On

• Ensure the gas line is properly installed.
• Replace the air filter element if dirty.
• Replace the gas supply line if restricted.
• Ensure the inlet pressure is 5.9 to 9.3 bar

(85 to 135 PSI).

With proper air connected, measure the

resistance between J5 pins 1 & 2.
• If short, replace the power board.
• If open, check the cable harness between

J5 and the pressure switch. If the harness

is good, replace the pressure switch (kit

228688).

• Perform Test 10.