Power SuPPly ComPonent rePlaCement

9-64

powermax

105 Service Manual

Replace the bulk capacitors

1. Remove the four bulk capacitor mounting screws from the power board.

Note: If the power supply is a 380 V CCC or 400 V CE model, the C152 top mounting screw will also secure

an inductor wire to the power board.

2. Remove the bulk capacitors, from the fan side of the power supply, by pulling them straight out.

3. Insert the new bulk capacitors, from the fan side of the power supply, noting the orientation of the polarity dot in

regard to the viewing hole in the power board.

4. Rotate each capacitor, from the fan side, until the polarity dot aligns with the viewing hole on the front side of the

power board.

5. Start the four supplied mounting screws by hand, then tighten to 40.3 kg cm (35 in.-lbs).

Note: If the power supply is a 380 V CCC or 400 V CE model, secure the inductor wire with the top C152

mounting screw.

Bulk capacitors

C151

C152

+

+

_

_

C151

C152

+

+

_

_

Mounting screws (4)

C151

C152

+

+

_

_

+

+

Bulk capacitor polarity dots

Power board viewing holes

Advertising