Basic system OperatiOns

3-4

powermax

105

Service Manual

Status screen

The status screen shows system status and fault information.

Torch started

Fault icon

Fault code

Torch is cutting

Remote

connected

Electrode end of life

detection manually disabled

Current setting (amps)

Current selection cursor

Pressure selection cursor

Pressure

setting

Visual pressure

setting

gas pressure indicators

In manual mode, the gas pressure is displayed in bar and psi. The gas pressure bar is also a visual indicator of the gas

pressure.

gas pressure bar

When the arrow is centered in the vertical bar (the reference pressure of the automatic pressure setting), the

gas pressure is set to the preset (factory-defined) value. If the pressure is higher than the preset value, the

arrow appears above the mid-point of the bar. If the pressure is lower than the preset value, the arrow appears

below the mid-point of the bar.

Note: In automatic mode, the power supply adjusts the pressure to the preset value. You can use manual

mode to adjust the pressure to satisfy the needs of a particular cutting job. Refer to page 3-10

Manually adjusting the gas pressure.

System status icons

The screen displays icons to indicate the system’s status.

torch started

Indicates that the torch has received a start signal.

torch is cutting

Indicates that the cutting arc has transferred to the metal and the torch is cutting.

Remote control

Indicates that a remote control or CNC is controlling the power supply using serial communications. All local

controls are disabled.

Electrode end-of-life detection manually disabled

Indicates that the electrode end-of-life detection feature is manually disabled.