2-13
Minimum inlet pressure (while gas is flowing)
This table shows the minimum required inlet pressure when the recommended inlet pressure is not available.
torch lead length
7.6 m (25 ft)
15.2 m (50 ft)
22.9 m (75 ft)
Cutting
5.2 bar (75 psi)
5.5 bar (80 psi)
5.9 bar (85 psi)
Gouging
4.1 bar (60 psi)
4.5 bar (65 psi)
4.8 bar (70 psi)
gas flow rates
Cutting
220 slpm (460 scfh, 7.7 scfm) at a minimum 5.9 bar (85 psi)
Gouging
230 slpm (480 scfh, 8.0 scfm) at a minimum 4.8 bar (70 psi)