Replace the coupler, Replace the gear rack, Replace the positioning sleeve – Hypertherm Powermax105 Service Manual User Manual

Page 308: Replace the torch lead, Powermax

Advertising
background image

Torch componenT replacemenT

10-18

powermax

105 Service Manual

Replace the positioning sleeve

Refer to the appropriate figure(s) on the previous page and complete the following instructions.
1. Slide the coupler off the end of the torch lead.
2. Slide the positioning sleeve (Duramax 180° full-length machine torch) off the end of the torch lead.
3. Slide the gear rack out of the groove in the positioning sleeve.
4. Slide the gear rack into the groove in the new positioning sleeve.
5. Slide the new positioning sleeve (Duramax 180° full-length machine torch) over the end of the torch lead.
6. Slide the coupler over the end of the torch lead.

Replace the torch lead

Refer to the appropriate figure(s) on the previous page and complete the following instructions.
1. Slide the coupler off the end of the torch lead.
2. Slide the positioning sleeve (Duramax 180° full-length machine torch) off the end of the torch lead.
3. Unscrew the strain relief body from the strain relief nut on the new torch lead.
4. Slide the positioning sleeve (Duramax 180° full-length machine torch) over the end of the new torch lead.
5. Slide the coupler over the end of the new torch lead.

Replace the gear rack

Refer to the appropriate figure(s) on the previous page and complete the following instructions.
1. Slide the gear rack out of the groove in the positioning sleeve.
2. Slide the new gear rack into the groove in the positioning sleeve.

Replace the coupler

Refer to the appropriate figure(s) on the previous page and complete the following instructions.
1. Slide the coupler off the end of the torch lead.
2. Slide the new coupler over the end of the torch lead.

Advertising
This manual is related to the following products: