Engine-driven generator recommendations

Generators used with the Powermax105 should satisfy the following requirements:

200–600 V CSA

3-phase, 50/60 Hz, 200–600 VAC (480 VAC recommended for best performance)

230–400 V CE

3-phase, 50/60 Hz, 230–400 VAC (400 VAC recommended for best performance)

380 V CCC/230–400 V CE

3-phase, 50/60 Hz, 230–400 VAC (400 VAC recommended for best performance)

400 V CE

3-phase, 50/60 Hz, 400 VAC (400 VAC recommended for best performance)

380 V CCC

3-phase, 50/60 Hz, 380 VAC (380 VAC recommended for best performance)

Engine drive

rating

System output

current

Performance

(arc stretch)

30 kw

105 A

Full

22.5–25

105 A

Limited

20 kw

85 A

Full

15 kw

70 A

Limited

15 kw

65 A

Full

12 kw

65 A

Limited

12 kw

40 A

Full

8 kw

40 A

Limited

8 kw

30 A

Full

Note: Based on the generator rating, age, and condition, adjust the cutting current as needed.

If a fault occurs while using a generator, turning the power switch quickly to OFF and then to ON again

(sometimes called a “quick reset”) may not clear the fault. Instead, turn OFF the power supply and wait 60 to

70 seconds before turning ON again.