Powermax, Specifications – Hypertherm Powermax105 Service Manual User Manual

Page 25

Advertising
background image

SpecificationS

powermax

105 Service Manual

1-7

EMC classification CISPR 11 (CE models only)

4

Class A

Input voltage (U

1

)/ Input current (I

1

) at

rated output (U

2 MAX

, I

2 MAX

) (See the

Power Supply Setup section for more

information.)

200–600 V CSA 200/208/240/480/600 V, 3-PH, 50/60 Hz

58/56/49/25/22 A

380 V CCC/

230–400 V CE

2,3

230-400 V, 3-PH, 50/60 Hz

50/29 A

230–400 V CE

2,3

230-400 V, 3-PH, 50/60 Hz

50/29 A

400 V CE

3,5

400 V, 3-PH, 50/60 Hz

28 A

380 V CCC 380 V, 3-PH, 50/60 Hz

30 A

Gas type

Air

Nitrogen

Gas quality

Clean, dry, oil-free per

ISO 8573-1 Class 1.2.2

99.95% pure

Recommended gas inlet flow rate/

pressure

Cutting: 220 slpm (460 scfh , 7.7 scfm) @ 5.9 bar (85 psi)

Gouging: 230 slpm (480 scfh, 8.0 scfm) @ 4.8 bar (70 psi)

1

Defined as a plot of output voltage versus output current.

2

Equipment complies with IEC 61000-3-12 provided that the short-circuit power S

sc

is greater than or equal to 5528

KVA at the interface point between the user’s supply and the public system. It is the responsibility of the installer or

user of the equipment to ensure, by consultation with the distribution network operator if necessary, that the equipment

is connected only to a supply with a short-circuit power S

sc

greater than or equal to 5528 KVA.

3

This product meets the technical requirements of IEC 61000-3-3 and is not subject to conditional connection.

4

WARNING: This Class A equipment is not intended for use in residential locations where the electrical power is

provided by the public low-voltage supply system. There may be potential difficulties in ensuring electromagnetic

compatibility in those locations, due to conducted as well as radiated disturbances.

5

Equipment complies with IEC 61000-3-12 provided that the short-circuit power S

sc

is greater than or equal to 4462

KVA at the interface point between the user’s supply and the public system. It is the responsibility of the installer or

user of the equipment to ensure, by consultation with the distribution network operator if necessary, that the equipment

is connected only to a supply with a short-circuit power S

sc

greater than or equal to 4462 KVA.