Basic system OperatiOns

3-10

powermax

105

Service Manual

Check the indicators

Verify the following:

• The green power ON LED on the front of the power supply is illuminated.
• The Fault LED is not illuminated.
• No error icons appear in the status screen.

If a fault icon appears in the status screen, or the Fault LED is illuminated, or the power ON LED is blinking, correct the

fault condition before continuing. More troubleshooting information is included later in this manual.

Manually adjusting the gas pressure

For normal operations, the power supply automatically adjusts the gas pressure. If you need to adjust the gas pressure

for a specific application, you can use manual mode to do so.

Note: Manual mode should be used by experienced users who need to optimize the gas setting (override the

automatic gas setting) for a specific cutting application.

When you switch from manual mode to automatic mode, the power supply automatically sets the gas pressure and the

amperage setting is unchanged. When you switch from automatic mode to manual mode, the power supply remembers

the previous manual gas pressure setting and the amperage setting is unchanged.

When you reset the power, the power supply remembers the previous mode, gas pressure, and amperage settings.

To adjust the pressure:
1. Press the automatic/manual pressure setting mode selector so that the LED next to the selector illuminates. Refer to

the diagram on page 3-2 Front controls and LEDs.

2. Press the current/gas selector until the selection cursor is opposite the gas pressure setting in the status screen.
3. Turn the adjustment knob to adjust the gas pressure to the desired level. Watch the arrow in the pressure bar as

you adjust the pressure.