105 a unshielded cutting (mild steel), 105 a unshielded cutting (mild steel) -39, Powermax – Hypertherm Powermax105 Service Manual User Manual

Page 111

Advertising
background image

Machine Torch SeTup

powermax

105 Service Manual

6-39

105 A Unshielded cutting (Mild Steel)

Air flow rate – slpm/scfh

Hot

217 / 460

Cold

250 / 530

Metric

Material

thickness

torch-

to-Work

Distance

Initial Pierce Height

Pierce

Delay time

best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

mm

mm

mm

%

seconds

(mm/min)

Volts

(mm/min)

Volts

6

4.6

9.2

200

0.5

4040

148

4980

145

8

3160

149

3770

145

10

2350

150

2700

145

12

1700

153

2080

147

16

0.6

980

155

1200

152

20

1.0

742

155

940

154

25

Edge Start

500

159

580

159

30

300

161

370

160

32

260

169

270

167

35

320

164

350

163

40

160

176

190

172

English

Material

thickness

torch-

to-Work

Distance

Initial Pierce Height

Pierce

Delay time

best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

inches

inches

inches

%

seconds

ipm

Volts

ipm

Volts

1/4

0.18

0.36

200

0.5

153

148

188

145

3/8

91

150

112

145

1/2

62

153

76

148

5/8

0.6

39

155

48

152

3/4

1.0

31

155

40

153

7/8

1.25

25

156

30

158

1

Edge Start

19

160

22

159

1-1/8

14

161

17

160

1-1/4

13

164

14

163

Advertising
This manual is related to the following products: