105 a shielded cutting (stainless steel), 105 a shielded cutting (stainless steel) -19, Powermax – Hypertherm Powermax105 Service Manual User Manual

Page 91

Advertising
background image

Machine Torch SeTup

powermax

105 Service Manual

6-19

105 A Shielded cutting (Stainless Steel)

Air flow rate – slpm/scfh

Hot

217 / 460

Cold

250 / 530

Metric

Material

thickness

torch-

to-Work

Distance

Initial Pierce Height

Pierce

Delay time

best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

mm

mm

mm

%

seconds

(mm/min)

Volts

(mm/min)

Volts

6

3.2

6.4

200

0.5

4870

139

6000

141

8

3460

141

4210

142

10

2240

144

2670

142

12

0.6

1490

148

1860

144

16

0.75

950

149

1080

149

20

8.0

250

1.25

660

154

810

152

25

Edge Start

440

158

530

156

30

340

164

360

160

32

300

166

320

163

English

Material

thickness

torch-

to-Work

Distance

Initial Pierce Height

Pierce

Delay time

best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

inches

inches

inches

%

seconds

ipm

Volts

ipm

Volts

1/4

0.125

0.25

200

0.5

185

139

224

141

3/8

94

143

112

142

1/2

55

148

68

145

5/8

0.75

38

149

43

149

3/4

0.31

250

1.25

28

153

34

151

7/8

Edge Start

22

156

27

153

1

17

158

20

156

1-1/8

14

162

16

159

1-1/4

12

166

13

163

Advertising