Machine interface pinout, Machine interface pinout -5, Powermax – Hypertherm Powermax105 Service Manual User Manual

Page 131

Advertising
background image

Mechanized cutting

powermax

105 Service Manual

7-5

3

4

12

13

14

5

6

Machine interface pinout

Refer to the following table when connecting the Powermax105 to a torch height controller or CNC controller with a

machine interface cable.

Signal

type

Notes

Connector sockets External cable wires

Start (start plasma) Input

Normally open.

18 VDC open circuit voltage at

START terminals. Requires dry

contact closure to activate.

3, 4

Green, black

Transfer (start

machine motion)

Output Normally open. Dry contact closure

when the arc transfers.

120 VAC/1 A maximum at the

machine interface relay.

12, 14

Red, black

Ground

Ground

13

Voltage divider

Output Divided arc signal of 20:1, 21.1:1,

30:1, 40:1, 50:1 (provides a

maximum of 15 V).

5 (-), 6 (+)

Black (-), white (+)