TroubleshooTing and sysTem TesTs

8-28

powermax

105

Service Manual

Fault

code

Description

Power

lED

Fault

lED

Fault

icon

Solutions

0-32-0

End of consumable life

On

On

• Replace the electrode and nozzle.
• Check the remaining consumables for wear

and replace as needed.

0-40-0

PFC/Boost IGBT module

under temperature

On

On

For an over-temperature fault:
• Leave the machine powered ON and

confirm that the fan is operating. Ensure

adequate air flow around the unit.

• Ensure the cover is placed with the air fins

on the fan side of the power supply.

• If the duty cycle has been exceeded, let

the unit cool and work within the duty cycle

limits listed in the Basic System Operations

section.

For an under-temperature (<-30°C or <-22°

F) fault:
• Move the unit to a warmer location.
• Perform Test 4.

0-40-1

PFC/Boost IGBT module

over temperature

0-40-2

Inverter IGBT module under

temperature

0-40-3

Inverter IGBT module over

temperature

0-50-0

*

Retaining cap off

On

On

• Verify that proper consumables and

retaining cap are installed. Replace

damaged parts. Refer to the Hand Torch

Setup or Machine Torch Setup section.

• Perform Test 8.
• If the consumables appear to be installed

correctly, the torch may be damaged. Test

with a known working torch.

• After correcting the problem, perform a

cold restart.

*We recommend that you perform a continuity check on the FastConnect receptacle on the power supply per the table

on page 8-29.