Power SuPPly ComPonent rePlaCement

powermax

105 Service Manual

9-79

3. Lift the PFC inductor out of the power supply, while carefully guiding the PFC inductor wires through the opening in

the bottom of the center panel.

Note: 230-400 V CE and 380 V CCC/230-400 V CE models have a ferrite core installed over the longer

PFC inductor wires, on the power board side, that must be removed while removing the PFC inductor

from the power supply.

4. Place the new PFC inductor in the power supply, while guiding the PFC inductor wires through the opening in the

bottom of the center panel.

5. Slide the tabs on the front of the PFC inductor into the slots in the base of the power supply.
6. Tighten the two supplied mounting screws in the base of the PFC inductor to 69.1 kg cm (60 in.-lbs).
7. If the power supply is a 230-400 V CE or 380 V CCC/230-400 V CE model, install the ferrite core over the longer

PFC inductor wires on the power board side of the power supply.

8. Secure the PFC inductor wires to the power board using the screw and bolt removed in an earlier step, while

referring to the applicable figure on the previous two pages. Tighten the screw to 40.3 kg cm (35 in.-lbs) and the

bolt at J25 to 63.4 kg cm (55 in.-lbs).

PFC Inductor

PFC Inductor wires (4)

Slot in base

Slot in base

PFC Inductor tab

PFC Inductor tab