Basic system OperatiOns

powermax

105 Service Manual

3-5

Fault codes

When a power supply or torch fault occurs, the system displays a fault code in the lower-left corner of the status screen

and displays a corresponding fault icon above the code. The first digit is always zero. The other two digits identify the

problem. Fault code information is included later in this manual.

Note: Only one fault code is displayed. If more than one fault occurs at the same time, only the fault code with the

highest priority is displayed.

Fault icons

The fault icons that appear on the left side of the status screen are described below. A fault code also appears to

identify the fault. Refer to the troubleshooting information later in this manual.

Warning

The system continues to run.

Fault

The system stops cutting. If you can not correct the problem and restart the system, contact your distributor

or Hypertherm Technical Service.

Error

The system requires service. Contact your distributor or Hypertherm Technical Service.

torch cap sensor

Indicates that the consumables are loose, improperly installed, or missing. Turn OFF the power, properly

install the consumables, and turn ON the system again to reset the power supply.

temperature

Indicates that the temperature of the power supply power module is outside the acceptable operating range.

gas

Indicates that the gas is disconnected from the rear of the power supply or there is a problem with the gas

supply.

Internal Serial Communications Interface

Indicates a problem with the SCI communications between the control board and the DSP board.