105 a shielded cutting (mild steel), 105 a shielded cutting (mild steel) -18, Powermax – Hypertherm Powermax105 Service Manual User Manual

Page 90

Advertising
background image

Machine Torch SeTup

6-18

powermax

105

Service Manual

105 A Shielded cutting (Mild Steel)

Air flow rate – slpm/scfh

Hot

217 / 460

Cold

250 / 530

Metric

Material

thickness

torch-

to-Work

Distance

Initial Pierce Height

Pierce

Delay time

best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

mm

mm

mm

%

seconds

(mm/min)

Volts

(mm/min)

Volts

6

3.2

6.4

200

0.5

4140

144

5090

145

8

0.75

3140

145

3870

145

10

2260

145

2790

145

12

1690

145

2060

148

16

1.0

1060

149

1310

149

20

780

152

940

152

25

Edge Start

550

159

580

158

30

370

162

410

161

32

350

166

370

161

35

290

168

320

165

40

190

173

210

170

English

Material

thickness

torch-

to-Work

Distance

Initial Pierce Height

Pierce

Delay time

best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

inches

inches

inches

%

seconds

ipm

Volts

ipm

Volts

1/4

0.125

0.25

200

0.5

156

144

192

145

3/8

0.75

94

145

116

145

1/2

62

146

76

148

5/8

1.0

42

149

52

149

3/4

33

151

40

150

7/8

1.25

26

154

30

157

1

Edge Start

21

160

22

158

1-1/8

15

162

17

160

1-1/4

14

166

15

161

1-1/2

9

171

10

168

Advertising