6 checking and changing q parameters, Procedure – HEIDENHAIN TNC 620 (73498x-01) ISO programming User Manual

Page 219

Advertising
background image

HEIDENHAIN TNC 620

219

8.6 Chec

king and c

h

anging Q

p

ar

amet

ers

8.6 Checking and changing

Q parameters

Procedure

You can check Q parameters in all operating modes (when writing,
testing and running programs) and also edit them.

U

If you are in a program run, interrupt it if required (for example, by
pressing the machine STOP button and the INTERNAL STOP soft
key). If you are in a test run, interrupt it.

U

To call Q-parameter functions, press the Q INFO soft

key or the Q key.

U

The TNC lists all parameters and their current values.

Use the arrow keys or the GOTO key to select the
desired parameter.

U

If you would like to change the value, press the EDIT

CURRENT FIELD soft key, enter the new value, and
confirm with the ENT key.

U

To leave the value unchanged, press the PRESENT

VALUE soft key or end the dialog with the END key.

You can have the Q parameters be shown in the additional status
display in the Manual, El. Handwheel, Single Block, Full Sequence and
Test Run operating modes.

U

If you are in a program run, interrupt it if required (for example, by
pressing the machine STOP button and the INTERNAL STOP soft
key). If you are in a test run, interrupt it.

U

Call the soft-key row for screen layout.

U

Screen layout with additional status display: In the

right half of the screen, the TNC shows the Overview
status form.

U

Press the STATUS OF Q PARAM. soft key

U

Press the Q PARAMETER LIST soft key

U

The TNC opens a pop-up window in which you can

enter the desired range for display of the
Q parameters or string parameters. Multiple
Q parameters are entered separated by commas (e.g.
Q 1,2,3,4). To define display ranges, enter a hyphen
(e.g. Q 10-14).

The parameters used internally or by the TNC in cycles are
provided with comments.

If you want to check or edit local, global or string
parameters, press the SHOW PARAMETERS Q QL QR QS
soft key. The TNC then displays the specific parameter
type. The functions previously described also apply.