Yaskawa i80M Appendix User Manual

Page 10

Advertising
background image

( O U T L I N E O F A L A R M N O . )

Z-AXIS

I

DIR.

I

D

IR

#0499

related error

Program error

#9000 –#9049

(Example)

ILLEGAL

:

There are unusable
characters other than
ISO/EIA code with
PS-232C during tape
operation.

MEMORY ERROR
(SET) :

Setting area total
check error
#9010
TH ERROR :
TH parity error during

tape 1/0 collation

#2000

Machine-related
error

#5000– #5999

Sequence error

(Example)

#2061
ZR AREA ERROR

(x) :

Reference point
return area error

( x )
#2190
MACHINE

UNREADY :

Machine set-up not
ready

#3000 –#3299

Emergency stop
for servo and
spindle,
CPU monitor

(Example)

#3041
PULSE EXCEED (X) :

Error pulse exceed (X)

#3270
POWER OFF ERROR
(KEEP MEM) :
Data error when the
power is turned OFF
( mainly system error)

Memory check
error, watchdog
timer error, off
line error

. BAT display

(Example)

ROM ERROR :
ROM check error
#8001
RAM ERROR :
RAM check error

Note : When an alarm occurs, the alarm number and message will be displayed on the
lower left part of the CRT. Refer to the pertinent itern in the Service Manual to cope with
the situation

an alarm occurs.