Yaskawa i80M Appendix User Manual
Page 166

9.2 PARAMETER NUMBER TABLE (Cent’d)
Parameter No.
N A M E
FORAX1
SOFF1
(Bit No.
7
6
5
4
2
1
o
)
X-axis rotating axis infinite length control not available.
X-axis rotating axis infinite length control available.
X-axis absolute encoder not provided.
X-axis absolute encoder provided.
No
processing during servo-off input.
Conducts
processing during servo-off input.
No error cutting during emergency stop input.
Conducts error cutting during emergency stop input.
Motor PG absolute encoder.
Separately-mounted PG absolute encoder.
Parameter No.
N A M E
FORAX2
ABS2
SOFF2
EXABS2
(Bit No.
7
6
5
4
3
2
1
O : Y-axis rotating axis infinite length control not available.
1: Y-axis rotating axis infinite length control available.
O : Y-axis absolute encoder not provided.
1: Y-axis absolute encoder provided.
O : No
processing during servo-off input.
1: Conducts
processing during servo-off input.
O : No error cutting during emergency stop input.
1 : Conducts error cutting during emergency stop input.
O : Motor PG absolute encoder.
1: Separately-mounted PG absolute encoder.
–
1 6 6
–