Alarm – Yaskawa i80M Appendix User Manual

Page 11

Advertising
background image

7.

7.1

NUMBERING OF THE ALARM NUMBERS

N u m b e r

0000

to

0049

0050

to

0099

0100

to

0499

1000

to

1099

2000

to

2199

3000

to

3299

5000

to

5999

8000

9000

None

BAT
display
BAT. AXI!

None

(

Warning
message

Details

and operation–related

that occur even in BG

and operation–related

that do not occur even

n BG

Program error

Program error
DNC, CMOS total etc.

Machine–related errors

reference point return,

machine preparation complete
in position, etc.

spindle axis related

ESP, CPU mutual monitoring

ladder message

macro alarm message

Memory check error
Watchdog timer error
Offline error

Errors that occur with BG
operation (Basically same as
0000–0049)

Battery error
Encoder alarm

When key operation error and
editing error are lit.

stop

Block stop

Block stop

Block stop

Block stop

Coasting
stop or
immediate
stop

stop ,
Servo off

Block stop

stop ,
Servo off

Not stop

Not stop

Not stop

R e s e t , m e t h o d , r e m a r k s

Input error
alarm

Reset

Input error Reset. However, power OFF
alarm

with 0050 and 0051

Input error
alarm

Reset

Input error
alarm

Reset

Reset after clearing cause.

Alarm

However, MRDY is automatic
reset with first OFF– ON of
power supply.

after clearing cause.

Alarm

However, SV OFF automati-
cally reset only with SV ON

Alarm

Correct cause, then reset.

Otherwise, just reset.

Exclusive maintenance screen

BG error

Soft key

output

Reset or just reset.

I

None

Replace battery

I

Warning Next key operation

Advertising