background image

Parameter No.

N A M E

TPDSPW

TM06

SETUP

(Bit No.

7

6

5

4

3

2

1

o

)

O : Subtool word display is ineffective.

1 : Subtool word display is effective.

O : Word display of tool pot invalid.
1: Word display of tool pot valid.

O : Intermediate pot display on ATC screen is ineffective.

1 : Intermediate pot display on ATC screen is effective.

O : If T command and M06 command are in the same

block, T command takes precedence.

1: If T command and M06 command are in the same

block, M06 command takes precedence.

O : Setup menu screen is effective.

.

screen is ineffective.

O : External timer display invalid.

0

.

‘TM ‘

Sp

External timer display valid.

Parameter No.

N A M E

SRCH2

SRCH 1

MDIRST

(Bit No.

7

6

5

4

3

2

1

o

)

O : Operation process address search is made by binary.
1: Operation process address search is made by character.

O : Editing process address search is made by binary.

1: Editing process address search is made by character.

O : Offset display input is fixed to absolute input.

0

.

. offse

t

f

to incremental

O : Work shift display input is fixed to absolute input.

0

.

.

fixed to incremental input.

O : Work

display is switched by soft keys.

: Work shift/offset display is switched

O : MDI operation starts from current cursor position.

0

.

.

MDI

operation starts from beginning of MDI program.

O : Panel reset and external reset clears MDI buffer.

MDI buffer.

O : If M02 or M30 is specified, MDI buffer is cleared when

operation is completed.

1: If M02 or M30 is specified, MDI buffer is not cleared

when

operation is completed.

– 2 2 9 –