Gantry_Power
This function block will enable or disable all axes configured as part of a gantry system. This block uses the
physical axis, then the secondary or prime axes are geared to the other axis in the same physical motion plane.
Parameters
*
Parameter
Data Type
Description
VAR_IN_OUT
V
Gantry
Contains all information pertaining to a gantry system.
VAR_INPUT
Default
B
Enable
BOOL
The function will continue to execute while
enable is held high.
FALSE
V
ClearAlarm
BOOL
This input will clear any axis specific
alarms on the Gantry axes
FALSE
VAR_OUTPUT
V
XAxisErrorID
UINT
ErrorID on the X axis
V
YAxisErrorID
UINT
ErrorID on the Y axis