Gantry_Power
This function block will enable or disable all axes configured as part of a gantry system. This block uses the
If the gantry is configured with dual motors on the same
physical axis, then the secondary or prime axes are geared to the other axis in the same physical motion plane.
Parameters
*
Parameter
Data Type
Description
VAR_IN_OUT
V
Gantry
Contains all information pertaining to a gantry system.
VAR_INPUT
Default
B
Enable
BOOL
The function will continue to execute while
enable is held high.
FALSE
V
ClearAlarm
BOOL
This input will clear any axis specific
alarms on the Gantry axes
FALSE
VAR_OUTPUT
V
XAxisErrorID
UINT
ErrorID on the X axis
V
YAxisErrorID
UINT
ErrorID on the Y axis