Y_digitalcamswitch, Parameters – Yaskawa MotionWorks IEC Toolboxes User Manual
Page 492

PLCopen Toolbox: Function Blocks
MotionWorks IEC61131-3 Toolboxes: 2013-09-13
479
Y_DigitalCamSwitch
This function block commands a group of discrete output bits analogous to a set of mechanical cam controlled
switches driven by a rotating shaft. Forward and backward movements are allowed. A maximum of 32 outputs
and 256 switches are supported.
Parameters
*
Parameter
Data Type
Description
VAR_IN_OUT
B
Axis
Logical axis reference. This value can be located on the
Configuration tab in the Hardware Configuration (logical
axis number).
B
Switches
Reference to the switching actions. 256 maximum
switches.
E
TrackOptions
Reference to the track related properties. 32 maximum
tracks.
VAR_INPUT
Default
B
Enable
BOOL
The function will continue to execute while