Un_modulesummation, Parameters – Yaskawa MotionWorks IEC Toolboxes User Manual
Page 381

Pack ML Toolbox: Function Blocks
MotionWorks IEC61131-3 Toolboxes: 2013-09-13
368
UN_ModuleSummation
The UN_ModuleSummation function block rolls up all the Equipment Module State Complete bits for active,
enabled EMs. The result is an overall PMLs State Complete bit that is transferred to the PackML_StateControl
function.
Parameters
*
Parameter
Data Type
Description
VAR_IN_OUT
V
UnitMachine
Structure containing all the information about the
machines current state and mode of operation for all
EMs and CMs
V
PML_Cmds
Structure that contains the current Unit mode of
operation and the commands sent by
PackML_StateMachine
VAR_INPUT
Default
B
Enable
BOOL
The function will continue to execute
while the enable is held high
FALSE
V
EM_Mask
WORD
Mask to deactivate EMs. When an EM is
deactivated, commands will not be sent
down to the EM, for testing purposes.
Each bit corresponds to the same
number EM to deactivate. (Example: to
16#0000