Reverse_mc_direction, Parameters, Error description – Yaskawa MotionWorks IEC Toolboxes User Manual
Page 487: Example

PLCopen Toolbox: Function Blocks
MotionWorks IEC61131-3 Toolboxes: 2013-09-13
474
Reverse_MC_Direction
This function block was designed for use with the Home_LS_Pulse function block in the PLCopen Toolbox. It
changes the enumerated type MC_Direction#positive_direction to MC_Direction#negative_direction or vice
versa so that the function can move the motor one direction into a limit switch with MC_StepRefLimit, and the
other direction when searching for the Index Pulse with MC_StepRefPulse.
Parameters
*
Parameter
Data
Type
Description
VAR_INPUT
Default
B
EN
BOOL
Enables the function.
FALSE
V
LimitDirection
INT
ENum
V
BackOffDistance
LREAL
INT#0
VAR_OUTPUT
B
ENO
BOOL
High if the function executed normally
V
PulseDirection
INT
MC_Direction#positive_direction or
MC_Direction#negative_direction
V
BackOffDirection
LREAL
Error Description
No Errors will result, but if there is a problem with the ENum input for MC_Direction, then ENO will be FALSE.
Example