Notes – Yaskawa MotionWorks IEC Toolboxes User Manual
Page 426

PLCopen Toolbox: Function Blocks
MotionWorks IEC61131-3 Toolboxes: 2013-09-13
413
V
LimitAccelNegative
LREAL
Parameter 1220
LREAL#0.0
V
LimitDecelPositive
LREAL
Parameter 1231
LREAL#0.0
V
LimitDecelNegative
LREAL
Parameter 1230
LREAL#0.0
VAR_OUTPUT
B
Valid
BOOL
Indicates that the outputs of the function are valid.
V
LimitAccDecEnableEcho
BOOL
Echo of Parameter 1222 ANDed with 1232
V
LimitAccelPositiveEcho
LREAL
Echo of parameter 1221 echoed from motion engine
V
LimitAccelNegativeEcho
LREAL
Echo of parameter 1220 echoed from motion engine
V
LimitDecelPositiveEcho
LREAL
Echo of parameter 1231 echoed from motion engine
V
LimitDecelNegativeEcho
LREAL
Echo of parameter 1230 echoed from motion engine
B
Error
BOOL
Set high if error has occurred during the execution of
the function block. This output is cleared when
'Execute' or 'Enable' goes low.
B
ErrorID
UINT
If Error is true, this output provides the Error ID. This
output is reset when 'Execute' or 'Enable' goes low.
Notes
The function block uses MC_ReadBoolParameter, MC_WriteBoolParameter, MC_ReadParameter, and
MC_WriteParameter.