Accdeclimits, Parameters – Yaskawa MotionWorks IEC Toolboxes User Manual
Page 425

PLCopen Toolbox: Function Blocks
MotionWorks IEC61131-3 Toolboxes: 2013-09-13
412
AccDecLimits
This function block manages the parameters associated with enabling/disabling the acceleration and
deceleration limits. The limits can be enabled or disabled and the values of the limits can be input and verified at
the output. The outputs are provided as an echo from the motion engine. This function allows for streaming of
variable limits.
Parameters
*
Parameter
Data
Type
Description
VAR_IN_OUT
B
Axis
Logical axis reference. This value can be located on the
Configuration tab in the Hardware Configuration
(logical axis number).
VAR_INPUT
Default
B
Enable
BOOL
The function will continue to execute
while enable is held high.
FALSE
V
LimitAccDecEnable
BOOL
Enables or Disables the Limit Accel
Decel function. Parameter 1222 and
1232 are combined
FALSE
V
LimitAccelPositive
LREAL
Parameter 1221
LREAL#0.0