Input signal connections, Important – Yaskawa Large Capacity Sigma II Series User Manual

Page 103

Advertising
background image

4.2 Settings According to Host Controller

4-27

4

„

Input Signal Connections

Connect the sequence input signals as shown below.

Provide an external input power supply; the SERVOPACK does not have an internal 24-V power sup-
ply.

• External power supply specifications: 24±1 VDC, 50 mA min.

Yaskawa recommends using the same external power supply as that used for output circuits. The
allowable voltage range for the 24-V sequence input circuit power supply is 11 to 25 V. Although a 12-
V power supply can be used, contact faults can easily occur for relays and other mechanical contacts
under low currents. Confirm the characteristics of relays and other mechanical contacts before using a
12-V power supply.

The function allocation for sequence input signal circuits can be changed.

See 4.3.3 Input Circuit Signal Allocation for more details.

→ Input +24VIN CN1-47

External I/O Power Supply Input

Speed/Torque
Control,
Position Control

I/O power

supply

SERVOPACK

Photocoupler

Host controller

+ 24 V IN

P-OT

N-OT

CN1-40

CN1-41

CN1-42

CN1-43

CN1-44

CN1-45

CN1-46

0 V

3.3 k

/S-ON

/P-CON

/ALM-RST

/P-CL

/N-CL

CN1-47

+24V

IMPORTANT