Appendix A List of Parameters
A-12
* When Pn50A.0 is set to 0 for the SGDB SERVOPACK, only the following modes are compati-
ble: Pn50A.1=7, Pn50A.3=8, and Pn50B.0=8.
Pn50C
0
/SPD-D Signal Mapping
(Internal Set Speed Selection)
0 to F
Same as above.
8: OFF
1
/SPD-A Signal Mapping
(Internal Set Speed Selection)
0 to F
Same as above.
8: OFF
2
/SPD-B Signal Mapping
(Internal Set Speed Selection)
0 to F
Same as above.
8: OFF
3
/C-SEL Signal Mapping
(Control Mode Switching)
0 to F
Same as above.
8: OFF
Pn50D
0
/ZCLAMP Signal Mapping
(Zero Clamping)
0 to F
Same as above.
8: OFF
1
/INHIBIT Signal Mapping
(Disabling Reference Pulse)
0 to F
Same as above.
8: OFF
2
/G-SEL Signal Mapping
(Gain Switching)
0 to F
Same as above.
8: OFF
3
(Reserved)
0 to F
Same as above.
8: OFF
Table A.3 Input Signal Selections (cont’d)
Parameter
Digit
Place
Name
Setting
Contents
Factory
Setting