6 Using the Digital Operator
6.1.6 Operation in Parameter Setting Mode
6-10
Repeat steps 2. to 6. as often as required.
Using the Panel Operator
1. Press the MODE/SET Key to select the parameter setting mode.
2. Press the Up or Down Cursor Key to select the parameter number to set. (Pn507 is
selected in this example.)
3. Press the DATA/SHIFT Key for a minimum of one second to display the current data for
the parameter selected at step2.
4. Press the Up or Down Cursor Key to change to the desired value of “00085.”
As you keep pressing the Up or Down Cursor Key, and the display changes faster.
5. Press the DATA/SHIFT Key for a minimum of one second to save the data. The display
will flash.
6. Press the DATA/SHIFT Key once more for a minimum of one second to return to the
parameter number display.
This has changed the setting of the parameter Pn507 from 100 to 85.
Repeat steps 2. to 6. as often as required.
Press the DATA/SHIFT Key for a maximum of one second to shift to a higher (left) digit.
Parameter numbers that are not defined are skipped during Operator operations.