6.2 Applied Operation
6-37
6
Using the Panel Operator
1. Press the MODE/SET Key to select the auxiliary function mode.
2. Press the Up or Down Cursor Key to select the parameter Fn011.
3. Press the DATA/SHIFT Key for a minimum of one second to display the servomotor
model and voltage code.
4. Press the MODE/SET Key to display servomotor capacity.
5. Press the MODE/SET Key to display the encoder type and resolution code.
Voltage
Servomotor Model
Code
Voltage
Code
Servomotor Model
00
100 VAC or 140 VDC
00
SGMAH
01
200 VAC or 280 VDC
01
SGMPH
02
400 VAC or 560 VDC
02
SGMSH
03
SGMGH-A (1500 min
-1
)
04
SGMGH-B (1000 min
-1
)
05
SGMDH
06
SGMUH
0B
SGMBH
Encoder Type
Encoder Resolution
Code
Type
Code
Resolution
00
Incremental encoder
13
13 bits
01
Absolute encoder
16
16 bits
17
17 bits
20
20 bits
MODE/SET
DATE/
Servomotor model
Voltage
Capacity: Displayed value
× 10 (W)
In this example, the capacity is 100 W.
Encoder type
Encoder resolution