Setting examples, Input circuit example – Yaskawa Large Capacity Sigma II Series User Manual

Page 91

Advertising
background image

4.2 Settings According to Host Controller

4-15

4

„

Setting Examples

Pn300 = 600: This setting means that 6 V is equivalent to the rated motor speed.

Parameter Pn300 can be used to change the voltage input range.

„

Input Circuit Example

• Always use twisted-pair cable for noise control.

Recommended variable resistor: Model 25HP-10B manufactured by Sakae Tsushin

Kogyo Co., Ltd.

Connect V-REF and SG to the speed reference output terminals on the host controller when
using a host controller, such as a programmable controller, for position control.

Adjust Pn300 according to output voltage specifications.

Adjust the speed reference input gain at the following parameter.

Speed Refer-

ence Input

Rotation

Direction

Motor Speed

SGMBH Servomotor

+6V

Forward rota-
tion

Rated motor speed

1500 min

-1

+1V

Forward rota-
tion

(1/6) rated motor
speed

250 min

-1

-3V

Reverse rota-
tion

(1/2) rated motor
speed

750 min

-1

Pn300

Speed Reference Input
Gain

Unit:

0.01V/rated motor

speed

Setting

Range:

150 to 3000

Speed
Control

EXAMPLE

+12 V

470 , 1/2W min.

2 k

SERVOPACK

CN1-5

CN1-6

SG

V-REF

Feedback
pulse input
terminals

Speed
reference
output
terminals

Host controller

SERVOPACK

: represents twisted-pair wires.

SG

V -REF

CN1-5

CN1-6

CN1-33
CN1-34
CN1-35
CN1-36

/PBO

PBO

/PAO

PAO

Advertising