4.2 Settings According to Host Controller
4-23
4
I/O Signals
I/O signals are described below.
Divided encoder signals are output.
Always connect these signal terminals when a position loop is formed in the host controller
for position control.
Set a dividing ratio at the following parameter.
The dividing ratio setting is not related to the gear ratio setting (Pn202 and 203) for the SER-
VOPACK electronic gear function during position control.
Output
→ PAO CN1-33
Encoder Output Phase A
Speed/Torque
Control,
Position Control
Output
→ /PAO CN1-34
Encoder Output Phase /A
Speed/Torque
Control,
Position Control
Output
→ PBO CN1-35
Encoder Output Phase B
Speed/Torque
Control,
Position Control
Output
→ /PBO CN1-36
Encoder Output Phase /B
Speed/Torque
Control,
Position Control
Output
→ PCO CN1-19
Encoder Output Phase C
Speed/Torque
Control,
Position Control
Output
→ /PCO CN1-20
Encoder Output Phase /C
Speed/Torque
Control,
Position Control
PG Dividing Ratio
Pn201