Using the panel operator – Yaskawa Large Capacity Sigma II Series User Manual
Page 234

6 Using the Digital Operator
6.1.6 Operation in Parameter Setting Mode
6-14
Using the Panel Operator
1. Press the MODE/SET Key to select the parameter setting mode.
2. Press the Up or Down Cursor Key to select the parameter number to set. (Pn000 is
selected in this example.)
3. Press the DATA/SHIFT Key for a minimum of one second to display the current data for
the selected parameter.
4. Press the DATA/SHIFT Key to select the digit to be set.
5. Press the Up or Down Cursor Key to select the value defined as a function setting for the
selected digit.
Repeat the above steps 4. and 5. for changing the data as required.
6. Press the DATA/SHIFT Key for a minimum of one second to save the data. The display
will flash.
7. Press the DATA/SHIFT Key once more for a minimum of one second to return to the
parameter number display.
This has changed the 1st digit of parameter Pn000 to “1.”
MODE/SET
DATE/
Digit to be set
Digit to be set
Digit to be set