A.6 Monitor Modes
A-15
A
A.6 Monitor Modes
The following list shows monitor modes available.
Parameter
Content of Display
Unit
Remarks
Un000
Actual motor speed
min
-1
-
Un001
Input speed reference
min
-1
-
Un002
Internal torque reference
%
Value for rated torque
Un003
Rotation angle 1
pulse
Number of pulses from the origin
Un004
Rotation angle 2
deg
Angle (electrical angle) from the ori-
gin
Un005
Input signal monitor
-
-
Un006
Output signal monitor
-
-
Un007
Input reference pulse speed
min
-1
-
Un008
Error counter value
reference
units
Amount of position error
Un009
Accumulated load rate
%
Value for the rated torque as 100%.
Displays effective torque in 10-s
cycle.
Un00A
Regenerative load rate
%
Value for the processable regenera-
tive power as 100%.
Displays regenerative consumption
power in 10-s cycle.
Un00B
Power consumed by DB resistance
%
Value for the processable power
when dynamic brake is applied as
100%.
Displays DB power consumption in
10-s cycle.
Un00C
Input reference pulse counter
-
Displayed in hexadecimal.
Un00D
Feedback pulse counter
-
Displayed in hexadecimal.