4 warning displays – Yaskawa Large Capacity Sigma II Series User Manual
Page 378

8.2 Troubleshooting
8-39
8
8.2.4 Warning Displays
The relation between warning displays and warning code outputs are shown in the following
table.
Note: OFF: Output transistor is OFF (high). ON: Output transistor is ON (low).
Table 8.6 Warning Displays and Outputs
Warning
Display
Warning Code Outputs
Warning Name
Meaning of Warning
ALO1
ALO2
ALO3
A.91
ON
OFF
OFF
Overload
This warning occurs before the overload alarms (A.71 or
A.72) occur. If the warning is ignored and operation con-
tinues, an overload alarm may occur.
A.92
OFF
ON
OFF
Regenerative Overload
This warning occurs before the regenerative overload
alarm (A.32) occurs. If the warning is ignored and opera-
tion continues, a regenerative overload alarm may occur.
A.93
ON
ON
OFF
Absolute Encoder Battery
Warning
This warning occurs when battery voltage for the absolute
encoder has dropped. If the warning is ignored and opera-
tion continues, a regenerative overload alarm may occur.