2 settings according to host controller, 1 speed reference – Yaskawa Large Capacity Sigma II Series User Manual
Page 90

4 Parameter Settings and Functions
4.2.1 Speed Reference
4-14
4.2 Settings According to Host Controller
This section describes the procedure for connecting a
Σ
-
ΙΙ Series Servo to a host controller,
including the procedure for setting related parameters.
4.2.1 Speed Reference
Input the speed reference using the following input signal speed reference input. Since this
signal has various uses, set the optimum reference input for the system created.
The above inputs are used for speed control (analog reference). (Pn000.1 = 0, 4, 7, 9, or A)
Always wire for normal speed control.
The motor speed is controlled in proportion to the input voltage between V-REF and SG.
→ Input V-REF CN1-5
Speed Reference Input
Speed Control
→ Input SG CN1-6
Signal Ground
Speed Control
Torque reference input
(analog voltage input)
Speed reference input
(analog voltage input)
SERVOPACK
Torque
reference
Speed
reference
: represents twisted-pair wires.
CN1-9
CN1-10
CN1-5
CN1-6
T-REF
SG
V-REF
SG
Input voltage (V)
-4
-8
-12
4
8
12
Factory setting
Rated motor speed
Rated motor speed
The slope is set in Pn300.