4 Parameter Settings and Functions

4.1.3 Limiting Torques

4-12

Confirm the allocation of input signals when using this function.(Refer to 4.3.3 Input
Circuit Signal Allocation
.) Factory settings are given in the following table.

The following output signals and monitor methods are used when torque is being lim-
ited.

Application Examples:

• Forced stop.
• Robot holding a workpiece.

Set the torque limits when the torque is limited by an external contact input.

See 4.2.10 Torque Limiting by Analog Voltage Reference, Function 1.

/P-CL

CN1-45 at low level
when ON

Use forward torque limit.

Limit:
Pn404

CN1-45 at high level
when OFF

Do not use forward torque limit. Normal
operation.

-

/N-CL

CN1-46 at low level
when ON

Use reverse torque limit.

Limit:
Pn405

CN1-46 at high level
when OFF

Do not use reverse torque limit. Normal
operation.

-

• /CLT
• Monitor Mode

Un005: Nos. 6 and 7 (With factory settings) (Refer to 6.1.7 Operation in Monitor Mode.)
Un006: Depending on output signal allocation conditions.

Condition that outputs a /CLT signal:
Pn50F.0 allocates an output terminal from SO1 to SO3.

Pn404

Forward External Torque
Limit

Unit:

%

Setting

Range:

0 to 800

Factory
Setting:

100

Speed/Torque
Control,
Position Control

Pn405

Reverse External Torque
Limit

Unit:

%

Setting

Range:

0 to 800

Factory
Setting:

100

Speed/Torque
Control,
Position Control

/P-CL (CN1-45) Input

Pn404 torque limit applied.

/N-CL (CN1-46) Input

Pn405 torque limit applied.