4.5 Forming a Protective Sequence

4-73

4

Note: See 4.3.3 Input Circuit Signal Allocation for other Pn50A.1 settings.

4.5.3 Using the Positioning Completed Output Signal

The basic use and wiring procedure for the positioning completed (/COIN) output signal
(photocoupler output signal) is described below. The signal is output to indicate that servo-
motor operation is completed.

This signal indicates that servomotor movement has been completed during position control.
The host controller uses the signal as an interlock to confirm on the host controller that posi-
tioning is completed.

Pn50A.1 Setting

Description

0

Enables the Servo ON (/S-ON) input signal. (The Servo is OFF when
CN1-40 is open, and is ON when CN1-40 is at 0 V.)

7

Disables the Servo ON (/S-ON) input signal. (The Servo is always ON,
and has the same effect as shorting CN1-40 to 0 V.)

Output

→ /COIN CN1-25

Positioning Completed Output Sig-
nal

Position Control

ON:

Circuit between CN1-25 and 26 is
closed, and CN1-25 is at low level.

Positioning is completed.
(Position error is below the setting.)

OFF:

Circuit between CN1-25 and 26 is open,
and CN1-25 is at high level.

Positioning is not completed.
(Position error is above the setting.)

Setting: Pn500 (positioning completed width)

SERVOPACK

Photocoupler output

(per output)

Maximum operating voltage:

30 VDC

Maximum output current:

50 mA DC

I/O power supply

CN1-25

CN1-26

/COIN+

/COIN-

+24V

0 V

Speed

Reference

Servomotor

/COIN

(CN1-25)

Pn500

Error pulse

(Un008)