Host command queue mode, Save sed key in controller, Fail disk for reading error – Areca ARC-8050T3U 6-Bay Thunder3 Desktop RAID Storage Array User Manual
Page 102: Web browser-based configuration
WEB BROWSER-BASED CONFIGURATION
102
“Legacy” – for motherboards that are using regular BIOS boot.
“UEFI” – for motherboards (especially Intel’s motherboards)
using UEFI boot
“EFI” – for Intel based MacPro boot
“Disable” – disable controller BIOS at POST (set to 0xFF)
==> If BIOS is to be disabled --> All data are 0xFF
• Host Command Queue Mode
This option is used to solve the the problem with reads stalling
that causes by out of order command completion. Choose the
“Host Command Queue Mode” option=”Ordered” on the “Ad-
vanced Configuration” if you want similar read/write through
-
puts. There the read and write get the same priority as they
are scheduled and the reads are not pushed back.
• Save SED Key In Controller
<a> If enable --> disable, clear SED Key saved in setup
<b> If disable --> enable, if key exists, save to setup
If enable--->disable, the key will not remain in the flash. So
that next time power up again, it will need to input the key
from the CLI or McRAID manager. You can also import the key
file (Import Security Key) or key-in the password (Enter SED
Key By Password) from the GUI interface.
• Fail Disk For Reading Error
This option is available to improve the fail disk function if the
disk has too many reading errors. This function is the option
that RAID controller will kill off the HDD for reading error ac-
count setting value.
- 3 errors in 70 seconds: this option also includes 4 errors in
100 seconds, 5 errors in 120 seconds
- 6 errors in 2 minutes: this option also includes 8 errors in
180 seconds, 10 errors in 240 seconds
- 9 errors in 3 minutes: this option also includes 12 errors in
270 seconds, 15 errors in 360 seconds
- Reading Error Does Not Fail Disk