Step 3. SNMP Service Method

With Areca series RAID controllers, there are 2 service methods to

get SNMP: in-band Thunderbolt port and onboard NIC.

1. Service Method-1: Using in-band Thunderbolt port (ArcHTTP

proxy server)

Pay attention to these:

Do not check mark the option: “SNMP Through PCI”.

Make sure you have the latest driver and ArcHTTP, from this

URL https://www.areca.com.tw/support/downloads.html

ArcHTTP supports sending “traps” only, do not support the

“get” command.

2. Service Method-2: Using onboard LAN port.

Pay attention to these:

Do not check mark the option: “SNMP Through PCI”.

• Do need to fill out the “SNMP Trap Config”.

C-3-1 Using ArcHTTP

The HTTP management software (ArcHTTP) runs as a service or

daemon, and has it automatically start the proxy for all control-

lers found. This way the controller can be managed remotely

without having to sign in the server. The ArcHTTP has also in-

tegrated the ability of sending SNMP trap. Please reference the

manual Chapter 3 “ArcHTTP Configuration” section to install and

setup its configuration.

Each RAID storage needs to have its own MIBs file. Areca provides

4 RAID storage MIBs file for users. User can request it if more con

-

trollers install on one system.

Note:

1. The MIB compiler may be not installed by default with SNMP

manager.

2. Some SNMP managers have unique rule on the format of

MIB files, you may need to refer the error message to

modify the mib file to be able to met the software

requirement.