High reliability, Hard drive failure prediction, Auto reassign sector – Areca ARC-8050T3U 6-Bay Thunder3 Desktop RAID Storage Array User Manual

Page 152: Appendix

Advertising
background image

APPENDIX

152

RAID controller allows user to choose the task priority (Ultra

Low (5%), Low (20%), Medium (50%), High (80%)) to bal

-

ance volume set access and background tasks appropriately.

For high array performance, specify an Ultra Low value. Like

volume initialization, after a volume rebuilds, it does not re

-

quire a system reboot.

High Reliability

Hard Drive Failure Prediction

In an effort to help users avoid data loss, disk manufacturers

are now incorporating logic into their drives that acts as an

"early warning system" for pending drive problems. This

system is called SMART. The disk integrated controller works

with multiple sensors to monitor various aspects of the drive's

performance, determines from this information if the drive

is behaving normally or not, and makes available status

information to RAID storage

firmware that probes the drive

and look at it.

The SMART can often predict a problem before failure occurs.

The controllers will recognize a SMART error code and notify

the administer of an impending hard drive failure.

Auto Reassign Sector

Under normal operation, even initially defect-free drive me

-

dia can develop defects. This is a common phenomenon. The

bit density and rotational speed of disks is increasing every

year, and so are the potential of problems. Usually a drive can

internally remap bad sectors without external help using cyclic

redundancy check (CRC) checksums stored at the end of each

sector.

The RAID controller drives perform automatic defect reassign-

ment for both read and write errors. Writes are always com-

pleted - if a location to be written is found to be defective, the

drive will automatically relocate that write command to a new

location and map out the defective location. If there is a re-

Advertising