124

3. Disconnect the BBM cable from J6 on the RAID storage con-

troller.

4. Disconnect the battery pack cable from JP2 on the BBM.

5. Install a new battery pack and connect the new battery pack

to JP2.

6. Connect the BBM to J6 on the RAID storage controller.

7. Secure the “Flat head screws” into the BBM.

B-8 BBM Specifications

Mechanical

• Module Dimension (W x H x D)

37.3 x 13 x 81.6 mm

Environmental

• Operating Temperature

* Temperature:

0

O

C to +40

O

C

(Charge)

0

O

C to +55

O

C (Discharge)

* Humidity: 45-85%, non-condensing

• Storage Temperature

* Temperature:

-20

O

C to +20

O

C (storing for less than 1year)

-20

O

C to +40

O

C (storing for less than 3months)

-20

O

C to +55

O

C (storing for less than 1month)

* Humidity: 45-85%, non-condensing

Electrical

Input Voltage

+3.6VDC

On Board Battery Capacity

1880mAH (1 * 1880mAH) for ARC-8050T3U RAID storage