APPENDIX
124
3. Disconnect the BBM cable from J6 on the RAID storage con-
troller.
4. Disconnect the battery pack cable from JP2 on the BBM.
5. Install a new battery pack and connect the new battery pack
to JP2.
6. Connect the BBM to J6 on the RAID storage controller.
7. Secure the “Flat head screws” into the BBM.
B-8 BBM Specifications
Mechanical
• Module Dimension (W x H x D)
37.3 x 13 x 81.6 mm
Environmental
• Operating Temperature
* Temperature:
0
O
C to +40
O
C
(Charge)
0
O
C to +55
O
C (Discharge)
* Humidity: 45-85%, non-condensing
• Storage Temperature
* Temperature:
-20
O
C to +20
O
C (storing for less than 1year)
-20
O
C to +40
O
C (storing for less than 3months)
-20
O
C to +55
O
C (storing for less than 1month)
* Humidity: 45-85%, non-condensing
•
Electrical
Input Voltage
+3.6VDC
•
On Board Battery Capacity
1880mAH (1 * 1880mAH) for ARC-8050T3U RAID storage