Appendix – Areca ARC-8050T3U 6-Bay Thunder3 Desktop RAID Storage Array User Manual

Page 123

Advertising
background image

123

APPENDIX

B-4 Battery Backup Capacity

Battery backup capacity is defined as the maximum duration

of a power failure for which data in the cache memory can be

maintained by the battery. The BBM’s backup capacity duration

can retain the cache content for a limited interval (typically 72

hours).

B-5 Operation

1. Battery conditioning is automatic. There are no manual pro-

cedures for battery conditioning or preconditioning to be per-

formed by the user.

2. In order to make sure of all the capacity is available for your

battery cells; allow the battery cell to be fully charged when

installed for the first time. The first time charge of a battery

cell takes about 24 hours to complete.

3. Set the “Disk Write Cache Mode”: Auto, if "Disk Write Cache"

option does not set on the “Auto”.

4. Set the volume set "Cache Mode": Write-Back Cache.

B-6 Battery Functionality Test Procedure

1. Write amount of data into controller volume, about 5GB or

bigger.

2. Waiting for few seconds, power failed system by remove the

power cable

3. Check the battery status, battery beeps every few seconds.

4. Power on system, and login in the RAID storage.

5. Check the controller event log; make sure the event shows

controller boot up with power recovered.

B-7 Changing the Battery Backup Module

At some point, the LI-ION battery will no longer accept a charge

properly. LI-ION battery life expectancy is anywhere from ap-

proximately 1 to 5 years.

1. Power down the RAID storage properly. Make sure that cache

memory has been flushed.

2. Remove all “Flat head screws” from the cabinet.

Advertising