2 spi mode, 5 error detection, 6 interrupts – Intel PXA255 User Manual

Page 510: 5 error detection -8 15.2.6 interrupts -8

Advertising
background image

15-8

Intel® PXA255 Processor Developer’s Manual

MultiMediaCard Controller

15.2.4.2

SPI Mode

SPI mode is an optional secondary communication protocol. In SPI mode, the MMCMD and
MMDAT lines are unidirectional and only single block data transfers are allowed. The MMCMD
signal is an output from the controller and sends the command token and write data to the MMC
card. The MMDAT signal is an input to the controller and receives the response token and read data
from the MMC card.

Note:

When the card is in SPI mode, the only way to return to MMC mode is by toggling the power to the
card.

Card addressing is implemented with hardware chip selects, MMCCS1 and MMCCS0. All
command, response, and data tokens are 8-bits long and are transmitted immediately following the
assertion of the respective chip select.

The command token is protected with a 7-bit CRC. The card always sends a response to a
command token. The response token has four formats, including an 8-bit error response. The length
of the response tokens is one, two, or five bytes.

SPI mode offers a non protected mode. In this mode, CRC bits of the command, response, and data
tokens are still required in the tokens but these bits are ignored by the card and the controller.

In write data transfers, the data is suffixed with an 8-bit CRC status token from the card. As in
MMC mode, the card may indicate that it is busy by pulling the MMDAT line low after the status
token. In read data transfers, the card may respond with the data or a data error token one byte long.

15.2.5

Error Detection

The MMC controller detects these errors on the MMC bus and reports them in the status register
(MMC_STAT):

Response CRC error: a CRC error was calculated on the command response.

Response time out: the response did not begin before the specified number of clocks.

Write data CRC error: the card returned a CRC status error on the data.

Read data CRC error: a CRC error was calculated on the data.

Read time out: the read data operation did not begin before the specified number of clocks.

SPI data error: a read data error token was detected In SPI mode.

15.2.6

Interrupts

The MMC controller generates interrupts to signal the status of a command sequence. The software
is responsible for masking the interrupts appropriately, verifying the interrupts, and performing the
appropriate action as necessary.

Interrupts and masking are described in

Section 15.5.11

and

Section 15.5.12

. The

CMDAT[DMA_EN] bit will also mask the MMC_I_MASK[RXFIFO_RD_REQ] and
MMC_I_MASK[TXFIFO_WR_REQ] interrupt bits.